Www.amgriffiths.co.uk
Stud walls to be 100mm thick comprising of 75 x 50 soft wood strutting, regularised and treated at 400 mm centres Ceilings to the underside of concrete floors shall be fixed to timber battens or proprietary galvanised 100 x 100mm softweed treated posts with 75 x 75mm cross rails ... Return Doc
Www.dot.ca.gov
REMOVING PORTIONS OF EXISTING ROOF COVERING. 2 PART 1 Deleterious matter that will decrease the effectiveness of the treatment shall be removed from all areas to be treated. The strainer screen shall have a open area equal to at least 3 times the cross-sectional area of pipe in ... Access Content
PLEASE NOTE: THIS IS AN EXAMPLE DRAWING OUR SPECIFICATIONS ...
INTERLOCKING CONCRETE ROOF TILES/ 3 50x38mm TREATED SW BATTENS 2 3 4 7 7 9 TREATED TIMBER BATTEN 18mm T&G FLOORING GRADE TIMBER 150 MIN TYPICAL SUSPENDED FLOOR DETAIL SCALE 1:10 Foundations: 600mm x 300mm DP with A393 mesh T&B 40mm Nom (See notes) ... Retrieve Document
SUSTAINABLE CONSTRUCTION GROUP - Home | Department Of Finance ...
Wood should be stored in otherwise recycle Windows (UPVC frame) Recycle (plastic deteriorates with age and sunlight) Slingsby ladder loft ladder Re-use External strip of roof covering rainwater Where indicated existing contaminated earth or backfill to be retained and treated ... Retrieve Content
Cms.walsall.gov.uk
24mm wood fibre board, Flexible flooring, Altro Marine 20 safety waterproof, non-slip Flexible flooring, Altro Walkway 20SD or Polysafe Decor Heavy Duty, ROOF COVERINGS INCLUDING FELT AND BATTENS, RIDGES, VERGES HIPS, IRONS, ETC. ... Fetch Full Source
** WARNING ** WARNING ** WARNING ** WARNING **
WOOD AND PLASTICS 104. 6.01 ROUGH CARPENTRY 104. DIVISION 7. snow roof and overhead doors to be installed. county, and contract number, with ample cross-references to the contract documents, to facilitate identification of items and their location in the work. ... View Document
MRP08 SOR As Amended
Coat of an approved wood primer, Supply and fit treated pine timber support stake 50mm x 75mm including saddles. and dispose of existing and supply and fix roof material as specified to 2 bedroom cottage including new concrete roof tiles, roof. battens & foil sarking. ... Fetch Here
AMERICAN GOTHIC PLAYHOUSE
Hoover Treated Wood Products, Inc. Mid-States Wood Preservers, Inc. Using 3/4” treated plywood, cut two flooring pieces, 4’x5’ and 2’-8”x5’. Enclose wall framing using treated 1x8 boards and 1x2 battens. NOTE : Interior can be finished with 3/8” treated plywood. ... Read Content
Www.pillar.saqnet.co.uk
Tiles shall be from Decra Roof Systems Ltd, Unit 7, Church Road Industrial Wooden battens and counter battens for tiling All small scantlings which cannot be pre-treated and any cross cut ends or notchings of the treated timber shall be liberally swabbed with a suitable solution ... View Doc
PLEASE NOTE: THIS IS AN EXAMPLE DRAWING OUR SPECIFICATIONS ...
For flooring grade insulation type & cross ventilation. Roof joist anchoring: Ensure ends of the roof joists are tied down to wall 50x25mm TREATED SW BATTENS 4 8 1 2 VAPOUR PERMEABLE UNDERLAY RAFTERS AT 600mm c/c MAX PROPRIETARY RAFTER VENTILATOR ... Read Document
PASSIVE WOODEN HOUSE - TMT 2013
The roof structure of the house with a loft consists of: tile, bars, roof cardboard plates 12.5 mm. The ceiling structure of the house with a loft consists of: flooring, sound insulation, ironing 2.2 cm , bearing timber structures cross battens , 42 mm Paroc insulation ... Read Full Source
MRP08 Schedule Of Rates - Effective From The 1st July 2011
Coat of an approved wood primer, stopped and puttied up and then to (Supply & install loft mount brackets) Supply & install loft Lift floor coverings (including vinyl, linoleum and carpets), underlays and fixings (such as battens, tacks, nails and staples) as directed – including ... View Doc
Peter Jackson Architects
38mm x 25mm treated s.w battens Sarking roof felt Trussed rafter roof, by specialist maker 10mm continous opening at eaves 22mm T&G wood flooring board (min. mass 15kg/m²) 75mm x 220mm SC3 timber joists @ max. 400mm centres 100mm mineral wool insulation Cross-Section Through Foundations ... Fetch Here
DICTIONARY
Accommodation Ladder. Sloping series of steps, usually of wood, fitted with handrails and extending from waterline to an entry into ship, Astronomical Cross Bearings. that are secured by hatch battens and wedges. Battened Sailss. ... Retrieve Content
AMERICAN GOTHIC PLAYHOUSE
Preservative treated wood shall be of hot-dipped galvanized steel, stainless steel, Using 3/4” treated plywood, cut two flooring pieces, 4’x5’ and 2’-8”x5’. 20.Cover roof framing with 1/2” treated plywood; ... Return Document
Replace composition shingle roof and deteriorated wood roof decking. replace failed flooring, health issue. Replace roof and door on fire sprinkler pump ouse, This building is used as a Red Cross Shelter for the Burlington-Edison School District community. ... Fetch This Document
Techincal Standards - Volume 3 - North East Lincolnshire
K20 Timber board flooring/ sarking Fix to raise tiling battens and lift roof tiles clear of trough tiles at eaves between all rafters to ensure free air space not less than required by Building Regulations for ventilation of roof space. P10/10 LOFT INSULATION: - Insulating ... Document Retrieval
DICTIONARY OF - Парусная Федерация ...
Lloyd's Signal Stations 205 Loft Template Method Log 206 Also called 'Jacob's Staff' or 'Cross The battens help to keep a taut sail when on a wind ... View Document
Can The - Green Frontier
Lean-to roof battens. Main verander roof battens. Nearby. Door. Recycled. Verander and lean-to cross-bracing. Porch roof (decorative to hide fibreboard) Studwork 1st flr (400mm centres approx) Flooring. 1.00 7.95 6.71 0.02 0.80 Wood. ... Read Document
No comments:
Post a Comment